How to determine water injection rate scientifically and
rationally is really a problem confronted in water injection
reservoirs. In this paper ,based on analyzing injection2production
system ,dividing coefficient was employed to establish models for
injection wells and production wells. Combining with a certain
reservoir ,calculating approach for single water injection well was
put out and calculating software was developed too. This method
and software were applied to the reservoir mentioned above and
relatively satisfactory result was obtained.