中子氧活化流量测试仪实流校准

2012年 34卷 第4期
阅读:84
查看详情
Actual flow calibration of flow-meter for neutron oxygen activation
张玮 王凤清 马文衡 王静 崔云生 刘文生
ZHANG Wei WANG Fengqing MA Wenheng WANG Jing CUI Yunsheng LIU Wensheng
华北油田公司采油工艺研究院,河北任丘 062552 渤海石油职业学院,河北任丘 062552
Production Technology Research Institute of Huabei Oil.eld Company PetroChina Renqiu 062552, China Bohai Petroleum Occupational Institute, Renqiu 062552, China
井下脉冲中子氧活化类流量测试仪是生产测井过程中进行真实井况复现的专用测井仪器,目前国内外尚无可靠、准确、安全的校准方法。为此,采用了油气水流量综合检定装置与地下模拟实验井衔接的方法解决此类测井仪实流标定问题,同时可进行油田生产测试常规井下流量测试仪器的校准,并在应用中不断改进完善。应用此方法已对 200多套井下流量含水测试仪器及氧活化类流量测井仪器实施了校准,实验表明该方法安全、可靠、有效。
Underground pulse neutron oxygen activation flow measurement is specific logging equipment for actual well condi-tion repeatability and reproducibility during production logging procedure. There is no as yet reliable, accuracy and safety calibration methods at home and aboard at present. According to this situation, adopting oil-gas-water flow comprehensive investigate equipment combining with underground stimulation well to solve the actual flow calibration of this logging wells. Meanwhile, this method could conduct the calibration of underground flow testing equipment for conventional production measurement in oilfield, and be improved continuously during the application. At present, More than 200 sets of underground flow water-bearing test equipment and oxygen activation flow logging equipment were calibrated by this method, and the results prove that the method is safe, reliable and effective.
氧活化测井; 地下模拟井; 辐射安全防护; 氧活化测试仪实流校准;
oxygen activation logging; underground stimulation well; safety for protection against radiation; actual flow calibra-tion of flow-meter for oxygen activation;