油基水泥浆堵剂的室内研究

1999年 21卷 第3期
阅读:105
查看详情
LAB RESEARCH OF OIL-BASED CEMENT SLURRY FOR SELECTIVE WATER SHUTOFF
杜伟程 吕光明 李书玲 王建东 黄柏宗
Du Weicheng Lu Guangming Li Shuting Wang Jiandong Huang Baizong
中国石油天然气集团公司工程技术研究院
结合堵水施工工艺,提出了一套简便的油基水泥浆堵剂室内评价方法,对研制的油基水泥浆堵剂的施工性能、水化性能及岩心试验进行了综合评价,对油基水泥浆堵剂的水化机理、选择性进行了初步探索。研究表明:油基水泥浆堵剂具有较高的水化强度及较强的堵水选择性,但注入性较差,在堵水作业中最好与注入性较好的其它堵剂联合使用.
Based on the operation process, this paper presents a simple lab method for evaluating the oil-based cement slurry for water shutoff. This paper comprehensively evaluates the mixing, hydration and core experiments of the slurry and primarily explores its hydration mechanism and selectivity. The study indicates that the developed oil-based cement slurry is with higher post-hydration compressed strength and better selectivity, but with poor injectivity. It is suggested that the slurry had better be injected together with other water shutoff agents with good injectivity.
油基水泥; 堵水剂; 选择性封堵; 岩心试验; 研究;
oil base cement; water shutoff; agent; selective plugging; core test research;
10.3969/j.issn.1000-7393.1999.03.012